Menu


Eaton/Moeller
EASY 205-ASI

Supply
voltage
Power dissipation Inputs,
digital
Inputs,
analog,
option (0-10 V)
Outputs,
digital (R=relay
T=transistor)
Outputs,
analog,
(0-10 V)
1 W -- --
LC display,
keypad
Week/
Year clock
Output
continuous current
Short-circuit proof
at cos phi = 1
Short-circuit proof
at cos phi=
0.5...0.7
Dimensions in inches
(W x H x D)
–/– -- -- -- 1.37 x 3.50 x 2.25

EASY205-ASI
EASY205-ASI indicated by the red arrow, EASY822 sold separately.

Even for straight-forward sequences, such as in production processes, the bus connection is worthwhile. The actuator sensor interface, AS-i for short, can supply 31 stations simultaneously with up to 248 binary instructions. AS-I is the ideal bus connection for mechanical engineering. Input and output data being transmitted in the particularly short time of only 5 ms means that, for example, several motors can be started at exactly the same time (e.g. in material handling).

The easy205-ASI communication module makes connecting to the bus particularly easy. It can be coupled centrally to any expandable easy basic units, such as the easy600, easy800 as well as the MFD-Titan devices via easy-Link. Simply wire the two core AS-I cable with the module – and that’s it! The data exchange is handled at a higher level via an AS-i Master.

easy205-ASI Dimensions

EASY205-ASI Dimensions

Let our expert sales staff guide you through finding the right products to fit your needs. CALL 866-595-9616.