3 phase
thermal magnetic motor protective devices |
|
TYPE
Article Number |
Description |
Amps |
Amps |
Hp @ 230 |
Hp @ 460 |
|
Bolt on Integrated Contactor |
S-PKZ2
|
AC Coil Contactor
(Specify Voltage) |
- |
|
15 |
30 |
|
S-G-PKZ2 |
DC Coil Contactor
(Specify Voltage) |
- |
|
15 |
30 |
|
S/HI20-S-PKZ2 |
AC Coil Contactor
(Specify Voltage) |
- |
|
15 |
30 |
|
Auxiliary Contacts |
|
Part # |
Description |
Normally Open |
Normally Closed |
|
Side mounted auxiliary contacts operate in
conjunction with the motor protector contacts. Can be mounted to a
motor protector or motor protector combination. Can be combines with
AGM trip indicating contacts. |
|
NHI11-PKZ2
|
Side
Mount Aux Contact for PKZ2 |
On PKZ2 |
|
1
normally open |
1
normally closed |
|
NHI22-PKZ2
|
Side
Mount Aux Contact for PKZ2 |
On PKZ2 |
|
2
normally open |
2
normally closed |
|
Type NHI-11S-PKZ2 has a set of contacts operated by
the motor protector, the other set by the contactor. Can be mounted
to motor protector combination. Can be combined with AGM trip
indicating contacts. |
|
NHI11S-PKZ2
|
Side
mount Aux Contact for PKZ2 and (/s) Contactor |
On PKZ2 |
|
1
normally open |
1
normally closed |
|
On Contactor |
|
-
|
-
|
|
HI11S/EZ-PKZ-2
|
Fits to
the side of separately mounted contactors |
On PKZ2 |
|
1
normally open |
1
normally open |
|
On Contactor |
|
1
normally open |
1
normally open |
|
NHI22S-PKZ2
|
Side
mount Aux Contact for PKZ2 and (/s) Contactor |
On PKZ2 |
|
2
normally open |
2
normally closed |
|
On Contactor |
|
-
|
-
|
|
NHI12-11S-PKZ2
|
Side
mount Aux Contact for PKZ2 and (/s) Contactor |
On PKZ2 |
|
1
normally open |
1
normally closed |
|
On Contactor |
|
1
normally open |
1
normally closed |
|
Axilliary
contact inserts -
Mounts in
the top portion of the contactor |
|
HI11-S-PKZ2 |
Replacement aux contacts for the built in ones on the contactor |
On Contactor |
|
1
normally open |
1
normally closed |
|
HI20-S-PKZ2
|
2
normally open |
- |
|
Trip Indicating Contacts, Trip Indicators
and Current Limiters
|
|
AGM...-PKZ2 provides trip differentiating contacts
and is supplied with K-AGM-PKZ2 red short-circuit indicator. Cab be
mounted to motor protector combinations. Can be combined with NHI...
or NHI...S. |
|
AGM2-11-PKZ2
|
Trip
Indicating Contacts for PKZ2 |
Transfers under
any trip condition |
Transfers only
on short circuit trip |
|
1 normally open
1 normally closed |
1 normally open
1 normally closed |
|
Provides
a visual signal of a short circuit trip condition via a resetable red flag
indicator. Differentiated trip signaling possible in conjunction
with handle position. |
|
K-AGM-PKZ2 |
Short circuit
indicator |
- |
- |
|
Fuseless,
current limiting set of contacts housed in a module. Increases short
circuit current rating of PKZ2/ZM up to 100kA/500V AC in IEC group
applications. Not UL/CSA.
Can be
mounted to motor protector or mounted separately on EZ base. |
|
CL-PKZ2
|
Current Limiter |
Max.
rated operational voltage Ue
= 690 V |
|
Shunt Trips and Undervoltage Trips |
|
Shunt trips are available in three models which
cover a wide range of AC and DC voltages. They can be used in
combination with R(E)(S)-PKZ2 remote control drives. |
|
A-PKZ2-A
|
Shunt Trip Module |
Trips the PKZ2 when external voltage is applied
Specify voltage and (Ac or DC )
24
V DC 48
V DC
60 V DC
24 V 50 Hz 48 V
50 Hz
24 V 60 Hz 48 V
60 Hz |
|
A-PKZ2-B
|
Shunt Trip Module |
Trips the PKZ2 when external voltage is applied
Specify voltage and (Ac or DC )
110
V DC 125
V DC
250 V DC
110 V 50 Hz 127 V
50 Hz 220 V 50 Hz
230 V 50 Hz 240 V
50 Hz
110 V 60 Hz 120 V
60 Hz 208 V 60 Hz
220 V 60 Hz 240 V
60 Hz |
|
A-PKZ2-C
|
Shunt Trip Module |
Trips the PKZ2 when external voltage is applied
Specify voltage and (Ac or DC )
380
V 50 Hz 400 V 50 Hz
415 V 50 Hz
440 V 50 Hz 500 V
50 Hz
480
V 60 Hz 600 V 60 Hz |
|
Can be combined with the motor protector to
accomplish Emergency-stop circuitry per IEC/EN 60 204. Can be used
in combination with R(E)(S)-PKZ2 remote control drives. |
|
U-PKZ2
(120V60HZ)
|
Under voltage Trip Module (for
AC) |
Trips the PKZ2 when external voltage is removed |
|
U-PKZ2
(24
V DC)
|
Under voltage Trip Module (for
DC) |
Trips the PKZ2 when external voltage is removed |
|
U-HI20-PKZ2
|
Under voltage Trip Module (for
AC) |
Trips the PKZ2 when external voltage is removed.
Includes a set
of early make contacts. In the trip position, both contacts will be
closed. The trip coil can be energized early by jumpering from the
contact, however in this move it will not be possible to combine it with
the R(E)(S)-PKZ2 remote control drives. |
|
Has a built in time delay to prevent tripping due to
momentary power losses of 200 ms or less. In the trip position, both
contacts will be closed. Can be used in combination with the
R(E)(S)-PKZ2 remote control drives. |
|
UVHI-PKZ2
(120V60HZ)
|
Drop-off delayed (200ms) |
For AC with
auxiliary contact |
|
Remote Control Drives
Remote
control drives can be used with both the motor protector and motor
protector combination. They are used to electrically
operate the
motor protector. They can be switched off at the device and
thumb-grip handle can be padlocked using a 6 mm padlock. Suitable
for use with either AC or DC voltages. Can be combined with undervoltage trips and shunt trips. Always used standard auxiliary
contact Type NHI when using remote control drives to electrically signal
the open or closed status of the motor protector. Remote control
drives cannot be used in conjunctions with the (R)H-PKZ2 door interlock
handle.
Mounting
is possible in both ON and OFF positions of the motor protector. An
internal electronic interlock always sets OFF as the default setting.
The thumb
grip handle has 2 positions: HAND and AUTO. In HAND: the drive
displays the color GREEN and blocks any remote electrical actuation.
The internal signaling contact 33/34 is open. In AUTO: the drive
displays the color RED, indicating that remote electrical actuation is
possible. The internal signaling contact 33/34 is closed. |
|
RE-PKZ2
(110-120V50/60HZ,DC)
|
Used to
electrically operate the PKZ2. Line voltage control.
OFF and RESET separate. |
Line
and control feeds have the same potential. The control section can
be energized by a single impulse of 15 ms duration, or by a maintained
contact. Upon energizing, the line connection draws its power
requirement (700 VA/W for a duration ms 30 ms) directly from the line.
Control section can also be actuated via auxiliary contacts from various
Moeller Electric components: NHI, AGM, ETR4-VS3, EK... and dry output
contacts from PLCs with no RC filter type surge suppression. |
|
RS-PKZ2
(24V50/60HZ,DC) |
Used to
electrically operate the PKZ2. Control voltage from external source
such as a PLC.
OFF equals RESET. |
|
RS-PKZ2
(110-120V50/60HZ,DC)
|
Used to electrically
operate the PKZ2. |
Line control sections are
galvanically separated. The control section is energized solely from
a 24V DC source by a single impulse or by a maintained contact.
Suitable for energizing directly from an electronic PLC output.
Upon energizing, the line
connection draws its power requirement (700 VA/W for a duration for 30 ms)
directly from the line. |
|
RS-PKZ2
(24V50/60HZ,DDC)
|
Used to electrically
operate the PKZ2. |
|
Magnetic Contactors
and Surge Suppressors |
|
Part # |
Amps |
Amps |
Number of contacts |
|
PKZ2 |
230 V |
460 V |
Normally Open |
Normally Closed |
|
|
|
NHI11-PKZ2
|
|
On PKZ2 |
|
|
1
normally open |
1
normally closed |
|
NHI22-PKZ2
|
|
On PKZ2 |
|
2
normally open |
2
normally closed |
|
Type NHI-11S-PKZ2 has a set of contacts operated by
the motor protector, the other set by the contactor. Can be mounted
to motor protector combination. Can be combined with AGM trip
indicating contacts. |
|
NHI11S-PKZ2
|
Side
mount Aux Contact for PKZ2 and (/s) Contactor |
On PKZ2 |
|
1
normally open |
1
normally closed |
|
On Contactor |
|
-
|
-
|
|
NHI11S/EZ-PKZ-2
|
Fits to
the side of separately mounted contactors |
On PKZ2 |
|
1
normally open |
1
normally open |
|
On Contactor |
|
1
normally open |
1
normally open |
|
NHI22S-PKZ2
|
Side
mount Aux Contact for PKZ2 and (/s) Contactor |
On PKZ2 |
|
2
normally open |
2
normally closed |
|
On Contactor |
|
-
|
-
|
|
NHI12-11S-PKZ2
|
Side
mount Aux Contact for PKZ2 and (/s) Contactor |
On PKZ2 |
|
1
normally open |
1
normally closed |
|
On Contactor |
|
1
normally open |
1
normally closed |
|
Axilliary
contact inserts -
Mounts in
the top portion of the contactor |
|
HI11-S-PKZ2
|
Replacement aux contacts for the built in ones on the contactor |
On Contactor |
|
1
normally open |
1
normally closed |
|
HI20-S-PKZ2
|
2
normally open |
- |
|
Accessories |
|
Separate Coils |
|
J-S-PKZ2
|
Separate coils are
available in AC voltages. RC type filters can also be supplied upon
request. |
|
Mounting Base |
|
EZ-PKZ2
|
Used to mount the S-PKZ2
contactor separately from the PKZ2 |
| |
|
Provides
easy access to the load side terminals of the PKZ2/SM motor protector for
control circuit tap off purposes when the protector and S-PKZ2 high
capacity magnetic contactor are mounted together as a combination unit
(PKZ2/ZM-.../S). Accepts 2.8 mm fast-on connectors
(insulated/non-insulated); control circuit conductor cross section range:
AWG 16...20, Cu only.
Max.
current draw: 1A or 15% of thermal dial (FLC) value, whichever is less.
Increase the setting of the dial accordingly to compensate for the tapped
off current. |
|
ST-PKZ2
|
Tap off's |
Provides line
voltage tap off after PKZ2 and before the contactor |
|
|
|
To mechanically interlock two S-PKZ2 contactors.
Contactors must be separately mounted using EZ-PKZ2 mounting bases.
Useful for reversing applications or when there is a need to mechanically
interlock the contactors of two PKZ2/ZM-.../S motor protector combinations
(e.g. 2-speed motors with 2 separate windings). Supplied with 4 end
brackets. |
|
MV-PKZ
|
Mechanical Interlock |
Provides mechanical
interlock between two (/s) contactors |
| |
|
Door/Cover Mounted Handle |
|
|
|
H-PKZ2 |
Black Handle |
Handle for external
mounting in control cabinets |
|
|
|
RH-PKZ2 |
Red Handle |
Handle for external
mounting in control cabinets |
|
|
|
A-H-PKZ2 |
Ext Shaft |
Extension shaft
from PKZ2 to door handle. Enclosure depth of 171 to 300mm. |
|
|
|
C-PKZ2 |
Clip Plate |
Combines the PKZ2
and the (/s) contactor into one din rail mountable device |
| |
|
B3.1/3-PKZ2 |
Buss Bar |
100 Amp - 3
Position buss bar. Use multiple units to daisy chain more. |
| |
|
B3.1/2-PKZ2 |
Buss Bar |
100 Amp - 2
Position buss bar. Use multiple units to daisy chain more. |
| |
|
BK50/3-PKZ2 |
Feeder Terminals |
3 Phase terminals
for buss bars. accepts wire size AWG 14-0 cu |
| |
Call us toll free at
866-595-9616 for superior technical support and immediate delivery of your
PKZ2 Accessories purchase today!
Wood Dale, Illinois
- Englewood, Florida
Local (941) 473-0073 - Fax (941) 473-0987