PKZ2 Accessories

3 phase thermal magnetic motor protective devices

TYPE

Article Number

Description Amps Amps Hp @ 230 Hp @ 460

Bolt on Integrated Contactor

S-PKZ2
AC Coil Contactor (Specify Voltage) -   15 30
S-G-PKZ2 DC Coil Contactor (Specify Voltage) -   15 30
S/HI20-S-PKZ2 AC Coil Contactor (Specify Voltage) -   15 30

 

Auxiliary Contacts

Part #

Description Normally Open Normally Closed
Side mounted auxiliary contacts operate in conjunction with the motor protector contacts.  Can be mounted to a motor protector or motor protector combination.  Can be combines with AGM trip indicating contacts.

NHI11-PKZ2

 

Side Mount Aux Contact for PKZ2

On PKZ2

1

normally open

1

normally closed

NHI22-PKZ2

 

Side Mount Aux Contact for PKZ2

On PKZ2

2

normally open

2

normally closed

Type NHI-11S-PKZ2 has a set of contacts operated by the motor protector, the other set by the contactor.  Can be mounted to motor protector combination.  Can be combined with AGM trip indicating contacts.

NHI11S-PKZ2

 

Side mount Aux Contact for PKZ2 and (/s) Contactor

On PKZ2

1

normally open

1

normally closed

On Contactor

-

 

-

 

HI11S/EZ-PKZ-2

 

Fits to the side of separately mounted contactors

On PKZ2

1

normally open

1

normally open

On Contactor

1

normally open

1

normally open

NHI22S-PKZ2

 

Side mount Aux Contact for PKZ2 and (/s) Contactor

On PKZ2

2

normally open

2

normally closed

On Contactor

-

 

-

 

NHI12-11S-PKZ2

 

Side mount Aux Contact for PKZ2 and (/s) Contactor

On PKZ2

1

normally open

1

normally closed

On Contactor

1

normally open

1

normally closed

Axilliary contact inserts -

Mounts in the top portion of the contactor

HI11-S-PKZ2

Replacement aux contacts for the built in ones on the contactor On Contactor

1

normally open

1

normally closed

HI20-S-PKZ2

 

2

normally open

-


Trip Indicating Contacts, Trip Indicators and Current Limiters
AGM...-PKZ2 provides trip differentiating contacts and is supplied with K-AGM-PKZ2 red short-circuit indicator.  Cab be mounted to motor protector combinations.  Can be combined with NHI... or NHI...S.

AGM2-11-PKZ2

Trip Indicating Contacts for PKZ2

Transfers under any trip condition

Transfers only on short circuit trip

1 normally open

1 normally closed

1 normally open

1 normally closed

Provides a visual signal of a short circuit trip condition via a resetable red flag indicator.  Differentiated trip signaling possible in conjunction with handle position.

K-AGM-PKZ2

Short circuit indicator - -

Fuseless, current limiting set of contacts housed in a module.  Increases short circuit current rating of PKZ2/ZM up to 100kA/500V AC in IEC group applications.  Not UL/CSA.

Can be mounted to motor protector or mounted separately on EZ base.

CL-PKZ2

 

Current Limiter Max. rated operational voltage Ue = 690 V
 
Shunt Trips and Undervoltage Trips
Shunt trips are available in three models which cover a wide range of AC and DC voltages.  They can be used in combination with R(E)(S)-PKZ2 remote control drives.

A-PKZ2-A

Shunt Trip Module

Trips the PKZ2 when external voltage is applied

 

         Specify voltage and (Ac or DC )       

24 V DC            48 V DC              60 V DC

24 V 50 Hz        48 V 50 Hz

24 V 60 Hz        48 V 60 Hz

A-PKZ2-B

Shunt Trip Module

Trips the PKZ2 when external voltage is applied

 

           Specify voltage and (Ac or DC )             

110 V DC            125 V DC             250 V DC

110 V 50 Hz        127 V 50 Hz         220 V 50 Hz

230 V 50 Hz        240 V 50 Hz

110 V 60 Hz        120 V 60 Hz         208 V 60 Hz

220 V 60 Hz        240 V 60 Hz

A-PKZ2-C

Shunt Trip Module

Trips the PKZ2 when external voltage is applied

 

           Specify voltage and (Ac or DC )              

380 V 50 Hz        400 V 50 Hz         415 V 50 Hz

440 V 50 Hz        500 V 50 Hz        

480 V 60 Hz        600 V 60 Hz

 

Can be combined with the motor protector to accomplish Emergency-stop circuitry per IEC/EN 60 204.  Can be used in combination  with R(E)(S)-PKZ2 remote control drives.

U-PKZ2
(120V60HZ)

Under voltage Trip Module (for AC)

Trips the PKZ2 when external voltage is removed

U-PKZ2
(24 V DC)

Under voltage Trip Module (for DC)

Trips the PKZ2 when external voltage is removed

U-HI20-PKZ2

Under voltage Trip Module (for AC)

Trips the PKZ2 when external voltage is removed.

Includes a set of early make contacts.  In the trip position, both contacts will be closed.  The trip coil can be energized early by jumpering from the contact, however in this move it will not be possible to combine it with the R(E)(S)-PKZ2 remote control drives.

Has a built in time delay to prevent tripping due to momentary power losses of 200 ms or less.  In the trip position, both contacts will be closed.  Can be used in combination with the R(E)(S)-PKZ2 remote control drives.

UVHI-PKZ2
(120V60HZ)

Drop-off delayed (200ms) For AC with auxiliary contact

 

Remote Control Drives

Remote control drives can be used with both the motor protector and motor protector combination.  They are used to electrically

 operate the motor protector.  They can be switched off at the device and thumb-grip handle can be padlocked using a 6 mm padlock.  Suitable for use with either AC or DC voltages.  Can be combined with undervoltage trips and shunt trips.  Always used standard auxiliary contact Type NHI when using remote control drives to electrically signal the open or closed status of the motor protector.  Remote control drives cannot be used in conjunctions with the (R)H-PKZ2 door interlock handle.

Mounting is possible in both ON and OFF positions of the motor protector.  An internal electronic interlock always sets OFF as the default setting.

The thumb grip handle has 2 positions: HAND and AUTO.  In HAND: the drive displays the color GREEN and blocks any remote electrical actuation.  The internal signaling contact 33/34 is open.  In AUTO: the drive displays the color RED, indicating that remote electrical actuation is possible.  The internal signaling contact 33/34 is closed.

RE-PKZ2
(110-120V50/60HZ,DC)

Used to electrically operate the PKZ2. Line voltage control.

OFF and RESET separate.

Line and control feeds have the same potential.  The control section can be energized by a single impulse of 15 ms duration, or by a maintained contact.  Upon energizing, the line connection draws its power requirement (700 VA/W for a duration ms 30 ms) directly from the line.

Control section can also be actuated via auxiliary contacts from various Moeller Electric components: NHI, AGM, ETR4-VS3, EK... and dry output contacts from PLCs with no RC filter type surge suppression.

RS-PKZ2
 (24V50/60HZ,DC)

Used to electrically  operate the PKZ2. Control voltage from external source such as a PLC.

OFF equals RESET.

RS-PKZ2
(110-120V50/60HZ,DC)

Used to electrically  operate the PKZ2.

Line control sections are galvanically separated.  The control section is energized solely from a 24V DC source by a single impulse or by a maintained contact.  Suitable for energizing directly from an electronic PLC output.

Upon energizing, the line connection draws its power requirement (700 VA/W for a duration for 30 ms) directly from the line.

RS-PKZ2 (24V50/60HZ,DDC)

Used to electrically  operate the PKZ2.

 

Magnetic Contactors and Surge Suppressors

Part #

Amps Amps Number of contacts
PKZ2 230 V 460 V Normally Open Normally Closed
 

NHI11-PKZ2

 

On PKZ2

 

1

normally open

1

normally closed

NHI22-PKZ2

 

On PKZ2

2

normally open

2

normally closed

Type NHI-11S-PKZ2 has a set of contacts operated by the motor protector, the other set by the contactor.  Can be mounted to motor protector combination.  Can be combined with AGM trip indicating contacts.

NHI11S-PKZ2

Side mount Aux Contact for PKZ2 and (/s) Contactor

On PKZ2

1

normally open

1

normally closed

On Contactor

-

 

-

 

NHI11S/EZ-PKZ-2

Fits to the side of separately mounted contactors

On PKZ2

1

normally open

1

normally open

On Contactor

1

normally open

1

normally open

NHI22S-PKZ2

Side mount Aux Contact for PKZ2 and (/s) Contactor

On PKZ2

2

normally open

2

normally closed

On Contactor

-

 

-

 

NHI12-11S-PKZ2

Side mount Aux Contact for PKZ2 and (/s) Contactor

On PKZ2

1

normally open

1

normally closed

On Contactor

1

normally open

1

normally closed

Axilliary contact inserts -

Mounts in the top portion of the contactor

HI11-S-PKZ2

Replacement aux contacts for the built in ones on the contactor On Contactor

1

normally open

1

normally closed

HI20-S-PKZ2

2

normally open

-

 

Accessories
Separate Coils

J-S-PKZ2

Separate coils are available in AC voltages.  RC type filters can also be supplied upon request.


Mounting Base

EZ-PKZ2

Used to mount the S-PKZ2 contactor separately from the PKZ2


 

Provides easy access to the load side terminals of the PKZ2/SM motor protector for control circuit tap off purposes when the protector and S-PKZ2 high capacity magnetic contactor are mounted together as a combination unit (PKZ2/ZM-.../S).  Accepts 2.8 mm fast-on connectors (insulated/non-insulated); control circuit conductor cross section range: AWG 16...20, Cu only.

Max. current draw: 1A or 15% of thermal dial (FLC) value, whichever is less.  Increase the setting of the dial accordingly to compensate for the tapped off current.

ST-PKZ2

Tap off's

Provides line voltage tap off after PKZ2 and before the contactor

 

To mechanically interlock two S-PKZ2 contactors.  Contactors must be separately  mounted using EZ-PKZ2 mounting bases.  Useful for reversing applications or when there is a need to mechanically interlock the contactors of two PKZ2/ZM-.../S motor protector combinations (e.g. 2-speed motors with 2 separate windings).  Supplied with 4 end brackets.

MV-PKZ

Mechanical Interlock

Provides mechanical interlock between two (/s) contactors

 
Door/Cover Mounted Handle

 

H-PKZ2

Black Handle

Handle for external mounting in control cabinets

 

RH-PKZ2

Red Handle

Handle for external mounting in control cabinets

 

A-H-PKZ2

Ext Shaft

Extension shaft from PKZ2 to door handle. Enclosure depth of 171 to 300mm.

 

C-PKZ2

Clip Plate

Combines the PKZ2 and the (/s) contactor into one din rail mountable device

 
B3.1/3-PKZ2 Buss Bar 100 Amp - 3 Position buss bar. Use multiple units to daisy chain more.
 
B3.1/2-PKZ2 Buss Bar 100 Amp - 2 Position buss bar. Use multiple units to daisy chain more.
 
BK50/3-PKZ2 Feeder Terminals 3 Phase terminals for buss bars. accepts wire size AWG 14-0 cu
 

Call us toll free at 866-595-9616 for superior technical support and immediate delivery of your PKZ2 Accessories purchase today!

   Wood Dale, Illinois  -  Englewood, Florida 
Local  (941) 473-0073 - Fax (941) 473-0987

Toll Free: 1 (866) 595-9616

 

Buy Klockner Moeller Direct from KMparts.com
 
- IN STOCK-

Our Mascot - Free rubber duck with every purchase!
Visit our Main Site at: KlocknerMoeller.com

 

For your convienance all Major Credit Cards Taken for Same Day Shipping of Moeller Electric Parts!
2005 PDF Catalog

EASY 500-700-800 PDF Brochure

2005 Automation PDF Catalog

KM News


A to Z Parts Index

Moeller Electric Catalogs

Search our Site

Klockner Moeller NZM4 - NZMH4 - NZM6 - NZM6B - NZM9 - NZM11 - NZM12 - NZM14
Moeller Electric Contactors. DIL0M - DIL0AM - DIL00M - DIL00AM - DIL1M - DIL1AM - DIL2M - DIL2AM - DIL3M - DIL4M115
Klockner NZM7 and NZM10
Moeller 11DIL - 11DILM -22DIL - 22DILM - 31DIL - 31DILM - 40DIL - 40DILM - 13DIL - 13DILM - 11SDILM - 22SDILM.
Moeller Electric Cam Switches
Klockner Moeller AT0 Safety Limit Switches
Moeller Electric timing Relays
Moeller DILET series timers to match the DILE series relays.
Klockner Motor Overload Protection Z00, Z1,Z2, Z3, Z4, Z5, ZE
Modular stack lights from Klockner Moeller