AT0
Safety Interlock Switches
|
|
The
AT0 operating head can be turned manually in 90 degree
stages to match the specified actuating surface and
direction of operation. Care should be taken during
mounting and operation that no foreign particles
penetrate the entry point of the actuator element.
For IP 65 protection use cable entry clamp. |
|
AT0-xx-1-ZB
Complete Switch, Including Actuator Element |
|
Contacts |
|
|
Normally
Open |
Normally
Closed |
 |
 |
| - |
1 |
AT0-01-1-ZB |
| 1 |
1 |
AT0-11-1-ZB |
| - |
2 |
AT0-02-1-ZB |
AT0-02-...FT-ZBZ
Personnel Protection |
 |
|
Door is opened |
Positive opening N.C. 21-22 contact opens |
|
Open door |
The
N.C. 21-22 contact is safely open, even
where attempts are made to tamper using
basic
tools |
|
Door is closed |
The
triple-coded actuator element re-closes
the N.C. contact |
|
|
AT0-xx-xxx-xFT-ZBZ/X
Safety Interlock Switches
with Mechanical Securing Actuator, Listed Below and
Sold Separately |
|
Contacts |
Voltage |
Spring-power activated
interlock switch
(power required to deactivate
interlock)
• with interlock monitoring and auxiliary release
mechanism
• monitoring of door position: continuous |
Electro-magnet activated interlock switch
(power required to activate
interlock)
• with interlock monitoring
• monitoring of door position: continuous |
Normally
Open |
Normally
Closed |
|
1 |
1 |
24 V DC |
AT0-11-24DFT-ZBZ/X |
AT0-11-24DMT-ZBZ/X |
|
- |
2 |
24 V DC |
AT0-02-24DFT-ZBZ/X |
AT0-02-24DMT-ZBZ/X |
|
1 |
1 |
120 V 50/60 Hz |
AT0-11-120AFT-ZBZ/X |
AT0-11-120AMT-ZBZ/X |
|
- |
2 |
120 V 50/60 Hz |
AT0-02-120AFT-ZBZ/X |
AT 0-02-120AMT-ZBZ/X |
|
1 |
1 |
230 V 50/60 Hz |
AT0-11-230AFT-ZBZ/X |
AT0-11-230AMT-ZBZ/X |
|
1 |
2 |
230 V 50/60 Hz |
AT0-02-230AFT-ZBZ/X |
AT0-02-230AMT-ZBZ/X |
|
Door closed and interlocked |
Requires no
power:
interlock also remains active under power loss
or wire breakage Interlocked door = safe state
N.C. enabling contact 21-22 is closed and allows
an operation e.g. machine run, to start |
| To
release door (deactivate interlock) |
Apply voltage
to the coil (A1, A2), e.g. from a
motion detector. The N.C. enabling contact
21-22 opens. The N.C. door monitoring contact
11-12 remains closed as long as the door
remains closed. |
|
Opening the door |
Only possible
once it is released. The N.C. door monitoring contact 11-12 opens to
indicate the open door. |
|
Door is open |
Only possible
once it is released. The N.C. door monitoring contact 11-12 opens to
indicate the open door. |
|
Re-closing the door |
Both contacts
are blocked open, even where attempts are made to tamper using basic
tools |
| To
interlock door |
N.C. enabling
contact 21-22. The N.C. door
monitoring contact 11-12 re-closes.
Remove voltage from coil:
1. Actuator is locked in.
2. The N.C. enabling contact 21-22 closes.
The enabling contact can only close when the
door is interlocked |
|
Call us toll free at
866-595-9616 for
superior technical support and
immediate delivery of your
AT0 Safety Interlock Switch purchase today!
Wood Dale, Illinois
- Englewood, Florida
Local (941) 473-0073 - Fax (941) 473-0987
Toll Free: 1 (866) 595-9616
Buy Klockner Moeller Direct from KMparts.com
- IN STOCK-

Visit our Main
Site at: KlocknerMoeller.com |
|
2005 PDF Catalog

EASY 500-700-800 PDF Brochure

2005 Automation PDF Catalog

KM News
 A to Z Parts Index
Moeller Electric Catalogs
Search our Site

|