Connectors |
Type |
|
Description |
For use with |
V0DILE |
 |
Provides a mechanical link when coupling two contactors
together.
Distance between Contactors = 0 mm |
DILEM |
DILM32-XVB |
 |
DILM7 - DILM12
DILM17 - DILM32
DILM40 - DILM65
DILM80 - DILM150 |
DILM150-XVB |
 |
DILM80 - DILM150 |
Mechanical Interlocks |
MVDILE |
 |
For two contactors with AC or DC operated magnet systems.
Distance between Contactors = 0 mm.
Mechanical Lifespan = 2.5 x 106 operations.
Additional auxiliary contact modules can be fitted. |
DILEM |
DILM12-XMV |
 |
For two contactors with AC or DC operated magnet systems.
Distance between Contactors = 0 mm.
Mechanical Lifespan = 2.5 x 106 operations.
Additional auxiliary contact modules can be fitted. |
DILM7 - DILM12
DILMP20 |
DILM32-XMV |
 |
DILM17 - DILM32 |
DILM65-XMV |
DILM40 - DILM65 |
DILM150-XMV |
DILM80 - DILM150 |
DILM500-XMV |
 |
For two contactors with the same or different magnetic
systems.
Mechanical lifespan 5 x 106 operations. No auxiliary contact
is possible
between the mechnical interlock and contactor.
Combination with same frame size only.
Distance between contactors: 15 mm |
DILM185 – DILM500 |
DILM820-XMV |
For two contactors with the same or different magnetic
systems.
Mechanical lifespan 5 x 106 operations. No auxiliary contact
is possible
between the mechnical interlock and contactor.
DILM820-XMV consists of interlock element and mounting
support plate. |
DILM580 – DILM1000 |
Reversing Kits |
MVS-WB-EM |
 |
Consisting of one 3-pole paralleling link with control
bridge and reversing link
with A2 bridge. |
DILEM
(+MVDILEM) |
DILM12-XRL |
 |
In addition to the electrical interlock, the following
control connections are
integrated:
• K1M: A1 – K2M: 21
• K1M: 21 – K2M: A1
• K1M: A2 – K2M: A1 |
DILM7/9/12 mains
DILM7/9/12 delta
DILM7/9/12 star |
DILM32-XRL |
|
DILM17/25/32 mains
DILM17/25/32 delta
DILM17/25/32 star |
Star-Delta Wiring Kits |
DILM12-XSL |
 |
The following control cables are integrated in addition to
electrical interlock:
• K3M: A1 – K5M: 21
• K3M: 21 – K5M: A1
• K3M: A2 – K5M: A1 |
DILM7/9/12 mains
DILM7/9/12 delta
DILM7/9/12 star |
DILM32-XSL |
|
DILM17/25/32 mains
DILM17/25/32 delta
DILM17/25/32 star |
Bridges |
Star-Point Bridges |
S1DILEM |
 |
Finger-safe (in accordance with IEC 536). |
DILEM |
DILM12-XS1 |
DILM7 - DILM12 |
DILM32-XS1 |
DILM17 - DILM32 |
DILM65-XS1 |
DILM40 - DILM65 |
DILM400-XS1 |
 |
A cover is included for protection against accidental
contact. |
DILM80 - DILM150 |
DILM500-XS1 |
DILM500 |
Paralleling Bridges (Consisting of two
paralleling links) |
P1DILEM |
 |
4th pole can be broken off.
AC-1 current carrying capacity of the open contactor
increases by a factor of
2.5.
Protected against accidental contact (in accordance with IEC
536). |
|
DILM12-XP1 |
 |
4th pole can be broken off.
AC-1 current carrying capacity of the open contactor
increases by a factor of
2.5.
Protected against accidental contact (in accordance with IEC
536).
Terminal capacity can be found in the Technical Data
section. |
|
DILM32-XP1 |
 |
DILM7 - DILM12 |
DILM32-XP1 |
DILM40 - DILM65 |
DILM185-XP1 |
 |
3-pole
AC-1 current carrying capacity of the open Contactor
increases by a factor of
2.5.
A cover is included for protection against accidental
contact. |
DILM185 |
Connection Tabs |
BT483 |
 |
1 x 6.3 x 0.8 or 2 x 2.8 x 0.8 mm
For auxiliary contact and coil connections.
Use connectors with insulated sleeves.
Standard quantity: 100
Must be ordered in standard quantity. |
DILEM
DILM185 –
DILM1000 |
BT2571 |
 |
DILM185 –
DILM1000 |
Terminal Blocks and Kits |
Cable Terminal Blocks |
DILM225-XKU-S |
 |
For cable connection. Single or double cables may be
connected.
See Technical Data for terminal capacity. |
DILM185
DILM225 |
DILM400-XKU-S |
DILM250 – DILM400 |
DILM500-XK-CNA |
Consists of three individual terminals (Cu, Al), with
integrated control circuit
terminal. Terminal cover included.
Terminal capacity: 2 X (AWG4 to MCM500) |
DILM500/22 |
DILM650-XK-CNA |
Consists of three individual terminals (Cu, Al), with
integrated control circuit
terminal. Terminal cover included.
Terminal capacity: 2 X (AWG2 to MCM500) |
DILM580/22
DILM650/22 |
DILM820-XK-CNA |
Consists of three individual terminals (Cu, Al).
Terminal capacity: 4 X (AWG2 to MCM500) |
DILM750/22
DILM820/22 |
Flat Strip Conductor Terminal Kit (with
Control Circuit Terminal consisting of 3 Flat Strip
Conductor Terminals) |
DILM650-XKB-S |
 |
For bus and flexibus connection. |
DILM500 – DILM650 |
DILM820-XKB-S |
DILM750
DILM820 |
Covers |
Sealable Shrouds |
HDILE |
 |
Cover snap-mounts onto the device and can be sealed to
prevent tampering. |
DILEM |
Terminal Cover |
DILM400-XHB |
 |
Protection against shock hazards and accidental contact. |
DILM185 – DILM400 |
DILM500-XHB |
DILM500 |
DILM650-XHB |
DILM580 – DILM650 |
DILM820-XHB |
DILM750 – DILM1000 |
|