Menu

Eaton
XTPEXRHM90B
Door Coupling Handle

XTPEXRHM90B Door Coupling Handle

XTPEXRHM90B shown


XTPEXRHM90B Door Coupling Handle

Description Color For Use With Old Moeller
Part Number
New Eaton
Part Number
Door
Coupling
Handle
Black For use as a main switch
to EN 60204 in MCC
power distribution systems
and with PKE installed
when rotated by 90°
PKE-XH-MCC XTPEXRHM90B

Plug-in extension shaft PKZ0-XAH can be cut to desired length for mounting depths of 100…240 mm Carrier with extension shaft included in delivery. With ON/OFF switch position and “+” (tripped), lockable with 3 padlocks, 4 – 8 mm hasp.



XTPEXRHM90B Door Coupling Handle Technical Data

Product range Accessories
Accessories Door coupling handle
For use with Door coupling handle PKE
For use as a main switch
to EN 60204 in MCC power distribution
systems and with PKE installed
when rotated by 90°
Color Black
Degree of Protection IP65
For use with PKE
Notes:
Plug-in extension shaft PKZ0-XAH can be cut to desired length for mounting depths of 100...240 mm
Carrier with extension shaft included as standard.
With ON/OFF switch position and "+" (tripped), lockable
With 3 padlocks, 4 - 8 mm hasp thickness.
ZFS... (except for ZFS-(L)TS-NZM) add-on front plates can be used.
Design verification as per IEC/EN 61439
Technical data for design verification
Rated operational current
for specified heat dissipation (In)
0 A
Heat dissipation per pole,
current-dependent (Pvid)
0 W
Equipment heat dissipation,
current-dependent (Pvs)
0 W
Static heat dissipation,
non-current-dependent (Pvs)
0 W
Heat dissipation capacity (Pdiss) 0 W
IEC/EN 61439 design verification  
10.2 Strength of materials and parts  
10.2.2 Corrosion resistance Meets the product standard's requirements.
10.2.3.1 Verification
of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification
of resistance of insulating materials
to normal heat
Meets the product standard's requirements.
10.2.3.3 Verification
of resistance of insulating materials
to abnormal heat and fire due
to internal electric effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation Please enquire
10.2.5 Lifting Does not apply,
since the entire switchgear
needs to be evaluated.
10.2.6 Mechanical impact Does not apply,
since the entire switchgear
needs to be evaluated.
10.2.7 Inscriptions Meets the product
standard's requirements.
10.3 Degree of protection of ASSEMBLIES Does not apply,
since the entire switchgear
needs to be evaluated.
10.4 Clearances and creepage distances Meets the product standard's
requirements.
10.5 Protection against electric shock Does not apply,
since the entire switchgear
needs to be evaluated.
10.6 Incorporation
of switching devices and components
Does not apply,
since the entire switchgear
needs to be evaluated.
10.7 Internal electrical circuits and connections Is the panel builder's responsibility.
10.8 Connections for external conductors Is the panel builder's responsibility.
10.9 Insulation properties  
10.9.2 Power-frequency electric strength Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage Is the panel builder's responsibility.
10.9.4 Testing of enclosures made
of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise Not applicable.
10.11 Short-circuit rating Is the panel builder's responsibility.
The specifications for the switchgear
must be observed.
10.12 Electromagnetic compatibility Is the panel builder's responsibility.
The specifications for the switchgear
must be observed.
10.13 Mechanical function The device meets the requirements,
provided the information in
the instruction leaflet (IL) is observed.
Technical data ETIM 5.0
Low-voltage industrial components (EG000017) / Door coupling handle for switchgear (EC000230)
Electric engineering, automation, process control engineering / Low-voltage switch technology /
Circuit breaker (LV < 1 kV) / Hand drive for switch devices
(ecl@ss8-27-37-04-15 [AKF013010])
With axis extension No
With door interlock No
Lockable No
With handle red/yellow No
Approvals
Product Standards UL 508; CSA-C22.2 No. 14;
IEC60947-4-1; CE marking
UL File No. E36332
UL Category Control No. NLRV
CSA File No. 165628
CSA Class No. 3211-05
North America Certification UL listed, CSA certified
Specially designed for North America No
Degree of Protection IEC: IP65, UL/CSA Type: 4X, 12

XTPEXRHM90B Door Coupling Handle Dimensions

Mounting depth: 152 to 267 mm from the top edge of the top-hat rail to the front edge of the cabinet door/cover [A] At least 100 mm from cover hinge

XTPEXRHM90B Dimensions

Inch to MM Conversion

Convert to MM

MM to Inch Conversion

Convert to Inches

Let our expert sales staff guide you through finding the right products to fit your needs. CALL 866-595-9616.