Eaton
XTPE065DCSSP
Motor-Protective Circuit-Breaker

XTPE065DCSSP Motor Starter

PKE65/AK/XTUW-32-SP shown


XTPE065DCSSP Motor Starter

Short Circuit Current Rating Setting Range
Overload Release
Ir
Old Moeller
Part Number
New Eaton
Part Number
240 V
kA
480 Y
277 V
kA
600 Y
347 V
kA
16.0 - 65.0A PKE65/AK/XTU-65-SP XTPE065DCSSP

XTPE065DCSSP Technical Data

Delivery programme
Basic function Type E DOL starters (complete devices)
Basic device MSC
Connection to
SmartWire-DT
No
Components for North America
Maximum Motor Rating
AC HP = PS
200 V 208 V HP 15
230 V 240 V HP 15
460 V 480 V HP 40
Short Circuit Current Rating
240 V kA 65
480 Y / 277 V kA 65
600 Y / 347 V kA 25
Setting range
Setting range of overload releases    Ir A 16 - 65
Short-circuit releases     
Non-delayed    Irm A 910
Motor-protective circuit-breakers PKE65/AK/XTU-65
Extension terminal BK50/3-PKZ4-E

Notes
The type E DOL starter (without protection) consists of a PKE65 motor-protective circuit-breaker with AK-PKZ0 and a BK50/3-PKZ4-E extension terminal.

Technical data
General
Standards IEC/EN 60947-4-1, VDE 0660
Main conducting paths
Rated impulse withstand voltage Uimp V AC 6000
Overvoltage category/pollution degree     III/3
Rated operational voltage Ue V 208 - 480
Rated operational current
Open, 3-pole: 50-60 Hz
380 V 400 V
Ie A 65
Additional technical data
Motor protective
circuit breaker PKZM0, PKE
PKE motor-protective circuit-breaker,
see motor-protective circuit-breaker
product group
Data for design verification according to IEC/EN 61439
Technical data for design verification
Heat dissipation capacity Pdiss W 0
IEC/EN 61439 design verification
10.2 Strength
of materials and parts
10.2.2 Corrosion
resistance
Meets the product standard's requirements.
10.2.3.1 Verification
of thermal
stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification
of resistance
of insulating materials
to normal heat
Meets the product standard's requirements.
10.2.3.3 Verification
of resistance
of insulating materials
to abnormal heat
and fire due to internal
electric effects
Meets the product standard's requirements.
10.2.4 Resistance
to ultra-violet
(UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting Does not apply, since the entire switchgear
needs to be evaluated.
10.2.6 Mechanical
impact
Does not apply, since the entire switchgear
needs to be evaluated.
10.2.7 Inscriptions Meets the product standard's requirements.
10.3 Degree
of protection
of ASSEMBLIES
Does not apply, since the entire switchgear
needs to be evaluated.
10.4 Clearances
and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock Does not apply, since the entire switchgear
needs to be evaluated.
10.6 Incorporation
of switching devices
and components
Does not apply, since the entire switchgear
needs to be evaluated.
10.7 Internal electrical
circuits and connections
Is the panel builder's responsibility.
10.8 Connections
for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties
10.9.2 Power-frequency electric strength Is the panel builder's responsibility.
10.9.3 Impulse
withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing
of enclosures made
of insulating material
Is the panel builder's responsibility.
10.10 Temperature
rise
The panel builder is responsible
for the temperature rise calculation.
 Eaton will provide heat dissipation data
for the devices.
10.11 Short-circuit
rating
Is the panel builder's responsibility.
The specifications for the switchgear
must be observed.
10.12 Electromagnetic compatibility Is the panel builder's responsibility.
The specifications for the switchgear
must be observed.
10.13 Mechanical
function
The device meets the requirements,
provided the information in
the instruction leaflet (IL) is observed.
Technical data ETIM 5.0
Low-voltage industrial components (EG000017) / Motor starter combination (EC001037)
Electric engineering, automation, process control engineering / Low-voltage switch technology /
Load breakout, motor breakout / Motor starter combination (ecl@ss8-27-37-09-05 [AJZ718009])
Setting range overload protector A 16 - 65
Adjustment range undelayed short-circuit release A 0 - 0
Phase failure sensitive - Yes
Switch off technique - Electronic
Rated operating voltage V 690 - 690
Rated permanent current Iu A 65
Rated operation power at AC-3, 230 V kW 18.5
Rated operation power at AC-3, 400 V kW 30
Connection type main current circuit - Screw connection
Device construction - Built-in device
fixed built-in technique
With integrated auxiliary switch - No
With integrated under voltage release - No
Number of poles - 3
Rated short-circuit breaking
capacity lcu at 400 V, AC
kA 80
Degree of protection (IP) - IP20

XTPE065DCSSP Dimensions

XTPE065DCSSP Dimensions

Inch to MM Conversion

Convert to MM

MM to Inch Conversion

Convert to Inches