View PDF |
| Interlock Activated |
Interlock Deactivated |
Door Open |
|

|

|
 |
| |
| Door closed and interlocked |
Requires power:
voltage is applied to the coil to activate
interlock; quicker access possible in the event of a
power loss or wire breakage.
Both the N.C. enabling contact 21-22 and the N.C.
door
monitoring 11-12 contact are closed |
| To release door (deactivate
interlock) |
Remove voltage
from the coil (A1, A2), e.g. from a motion detector.
The N.C. enabling contact 21-22 opens. The N.C.
monitoring contact 11-12 remains closed as long as
the door remains closed. |
| Opening the door |
Only possible once
door is released (interlock deactivated). The N.C.
monitoring contact 11-12 opens to indicate the open
door. |
| Door Open |
Both contacts are
blocked open, even where attempts
are made to tamper using basic tools. |
| Re-closing the door |
Triple-coded
actuator removes the block on the N.C. enabling
contact 21-22. The N.C. door monitoring contact 11-
12 re-closes. |
| To interlock door |
Reapply voltage to
coil:
1. Actuator is locked in.
2. The N.C. enabling contact 21-22 closes.
The enabling contact can only close when the door is
interlocked. |
| |
Call us toll free at
866-595-9616 for
superior technical support and
immediate delivery of your
AT0-02-24DMT-ZBZ/X Limit Switch purchase today!
Wood Dale, Illinois
- Englewood, Florida
Local (941) 473-0073 - Fax (941) 473-0987
Toll Free: 1 (866) 595-9616
Buy Klockner Moeller Direct from KMparts.com
- IN STOCK-

Visit our Main
Site at: KlocknerMoeller.com |
|
2005 PDF Catalog

EASY 500-700-800 PDF Brochure

2005 Automation PDF Catalog

KM News
 A to Z Parts Index
Moeller Electric Catalogs
Search our Site

|