AT0-11-230AMT-ZBZ/X

Electro-Magnet activated interlock switch
(power required to activate interlock)
• with interlock monitoring
• monitoring of door position: continuous

AT0-11-230AMT-ZBZ/X
 
Contacts Positive
Opening Clearance
 to IEC/EN
60 947-5-1
Control Voltage
Supply to Magnetic Coil
Circuit Diagram
Normally Open Normally Closed
AT0-11-230AMT-ZBZ/X 1 1 230 V 50/60Hz Moeller Electric AT0-11-230AMT-ZBZ/X Circuit Diagram
AT0-...-ZBZ/X, Dimensions and Data View PDF
Interlock Activated Interlock Deactivated Door Open

 
Door closed and interlocked Requires power: voltage is applied to the coil to activate interlock; quicker access possible in the event of a power loss or wire breakage.
Both the N.C. enabling contact 21-22 and the N.C. door
monitoring 11-12 contact are closed
To release door (deactivate interlock) Remove voltage from the coil (A1, A2), e.g. from a motion detector. The N.C. enabling contact 21-22 opens. The N.C. monitoring contact 11-12 remains closed as long as the door remains closed.
Opening the door Only possible once door is released (interlock deactivated). The N.C. monitoring contact 11-12 opens to indicate the open door.
Door Open Both contacts are blocked open, even where attempts
are made to tamper using basic tools.
Re-closing the door Triple-coded actuator removes the block on the N.C. enabling
contact 21-22. The N.C. door monitoring contact 11-
12 re-closes.
To interlock door Reapply voltage to coil:
1. Actuator is locked in.
2. The N.C. enabling contact 21-22 closes.
The enabling contact can only close when the door is interlocked.
 



Call us toll free at 866-595-9616 for superior technical support and immediate delivery of your AT0-11-230AMT-ZBZ/X Limit Switch purchase today!

   Wood Dale, Illinois  -  Englewood, Florida 
Local  (941) 473-0073 - Fax (941) 473-0987

Toll Free: 1 (866) 595-9616

 

Buy Klockner Moeller Direct from KMparts.com
 
- IN STOCK-

Our Mascot - Free rubber duck with every purchase!
Visit our Main Site at: KlocknerMoeller.com

 

For your convienance all Major Credit Cards Taken for Same Day Shipping of Moeller Electric Parts!
2005 PDF Catalog

EASY 500-700-800 PDF Brochure

2005 Automation PDF Catalog

KM News


A to Z Parts Index

Moeller Electric Catalogs

Search our Site

Klockner Moeller NZM4 - NZMH4 - NZM6 - NZM6B - NZM9 - NZM11 - NZM12 - NZM14
Moeller Electric Contactors. DIL0M - DIL0AM - DIL00M - DIL00AM - DIL1M - DIL1AM - DIL2M - DIL2AM - DIL3M - DIL4M115
Klockner NZM7 and NZM10
Moeller 11DIL - 11DILM -22DIL - 22DILM - 31DIL - 31DILM - 40DIL - 40DILM - 13DIL - 13DILM - 11SDILM - 22SDILM.
Moeller Electric Cam Switches
Klockner Moeller AT0 Safety Limit Switches
Moeller Electric timing Relays
Moeller DILET series timers to match the DILE series relays.
Klockner Motor Overload Protection Z00, Z1,Z2, Z3, Z4, Z5, ZE
Modular stack lights from Klockner Moeller