Menu

Eaton/Moeller
FAZ-XIS2/6
Miniature Circuit Breaker Overview

FAX Circuit Breaker Overview

FAZ miniature circuit-breakers 1
Characteristics/rated current ranges
B/4 – 63 A; C/0.5 – 63 A; D/6 – 40 A
S/1 – 16 A; R/2 – 50 A
Switching capacity:
10 kA to IEC/EN 60898
B, C, D characteristic
4.5 kA to IEC/EN 60947-2
S characteristic
6 kA to IEC/EN 60947-2
R characteristic
1-, 1N-, 2-, 3-, 3N-, 4-pole
(S:1-, 2-pole; R:1-, 2-, 3-pole)
Special miniature circuit-breaker for
auxiliary circuits (1- or 2-pole)
Special miniature circuit-breaker for DC
applications up to 500 V DC
FAZ-PN miniature circuit-breaker 2
Characteristic/rated current ranges
B/6 – 40 A; C/2 – 40 A
Switching capacity:
6 kA to IEC/EN 60898
B, C characteristic
1N-pole
Miniature circuit-breaker with
residual-current protective module
3

Overload, short-circuit and fault current
protection
Characteristic/rated current ranges:
B/10 – 63 A; C/10 – 63 A; 2- or 4-pole
Switching capacity:
15 kA to IEC/EN 60947-2
Rated fault current 30 mA, 300 mA
FILS combined RCD/MCB devices 4
Overload, short-circuit and fault current
protection
Characteristic/rated current ranges:
B/6 – -40 A; C/6 – -40 A; 1N-pole
Switching capacity:
10 kA to IEC/EN 60898
Rated fault current 30 mA, 300 mA
Residual current circuit-breakers 5
Alternating-current sensitive
2-pole 16 – 80 A
4-pole 25 – 80 A
Pulse-current sensitive
2-pole 16 – 40 A,
4-pole 25 – 125 A
Rated fault current
30 mA, 100 mA, 300 mA, 500 mA
4-pole selective, 63 – 80 A
Rated fault current
100 mA, 300 mA
AZ miniature circuit-breakers 6
Characteristic/rated current ranges:
C/20 – 125 A; D/50 – 100 A
Switching capacity:
15 – 25 kA to IEC/EN 60947-2
1-, 2-, 3-, 3N-, 4-pole
FAZ auxiliary contacts 7
Standard auxiliary contacts
Trip-indicating auxiliary contacts
Auxiliary contacts
AZ auxiliary contacts 8
Standard auxiliary contacts
FAZ voltage release 9
Undervoltage release
Shunt release;
can be fitted to FAZ or FAZ-FIM
AZ voltage release 10
Shunt release
Remote switching module 11
Suitable for remote switching and
automatic re-closing of an m.c.b. or an
r.c.c.b., for remote trip testing of an r.c.c.b.
in connection with a remote testing
module
Reclosing module 11
for automatic reclosing of FAZ circuitbreakers
and FI/FIP residual-current circuit
breakers
Remote testing module 12
Suitable for remote trip testing at the rated
fault current of an r.c.c.b.
Residual-current protective module
for AZ high-capacity miniature circuitbreakers
13

Rated fault current
30 mA, 300 mA, 500 mA, 1 A
Alternating-current sensitive
2/4-pole up to 125 A
Pulse-current sensitive
2/4-pole up to 125 A
Selective
4-pole up to 125 A
 

212125
 FAZ-XIS2/6
FEEDER BUS

212135
 FAZ-XIS2/6-HI
FEEDER BUS


Let our expert sales staff guide you through finding the right products to fit your needs. CALL 866-595-9616.