EMR4-N... liquid level monitoring relays
|
Part Name Image |
Description |
Supply voltage |
Response sensitivity |
|

|
EMR4-N100-1-B |
- Monitors the level of conductive liquids
- Monitors the ratio of mixtures of conductive liquids
- Selectable: protection against running dry or overflowing
|
220 – 240 V AC |
5 Ώ – 100 kΏ |
 |
EMR4-N500-2-B |
- Monitors the level of conductive liquids
- Monitors the ratio of mixtures of conductive liquids
- Selectable On-delay or Off-delay between 0.5 – 10 s
|
250 Ώ – 500 kΏ |
EMR4-N500-2-A |
- Monitors the level of conductive liquids
- Monitors the ratio of mixtures of
conductive liquids
- Selectable On-delay or Off-delay between
0.5 – 10 s
|
24 – 240 V AC/DC |
EMR4-R... insulation monitoring relays
|
Part Name Image |
Description |
Supply voltage |
Insulation resistance range Ώ |

|
EMR4-RDC-1-A |
- Monitors the insulation resistance in nonearthed DC supply systems
- Selector switch for open- or closed-circuit principle
- With test and reset facilities
- Status indication via LEDs
|
24 – 240 V AC/DC |
10 – 110 kΏ |
EMR4-RAC-1-A |
- Monitors the insulation resistance between non-earthed AC supply systems and the protective conductor/earth
- Tripping function memory
- Insulation monitoring in 1- and 3-phase AC supply systems
- Test via local test button or remote test operation
- Status indication via LEDs to VDE 0413 / Part 2
|
EMR4-I... current monitor relays |
Part Name Image |
Description |
Supply voltage |
Current measuring range |

|
EMR4-I1-2-A |
- Switching hysteresis adjustable from 5 – 30 %
- Response delay 0.1 – 30 s
- EMR4...-A: monitors one upper or lower limit
- EMR4...-B: monitors one upper limit
- Extension of the measurement range possible with current transformers
|
24 – 240 V AC/DC |
3 – 30 mA 10 – 100 mA 0.1 – 1 A |
| EMR4-I15-2-A |
0.3 – 1.5 A 1 – 5 A 3 – 15 A |
| EMR4-I15-2-B |
220 – 240 V AC |
0.3 – 1.5 A 1 – 5 A 3 – 15 A |
EMR4-F... phase sequence relay
|
Part Name Image |
Description |
Supply voltage |
Monitoring voltage |

|
EMR4-F500-2 |
- Monitors three-phase systems for phase sequence and phase failure

- Supply voltage = voltage being monitored
|
200 – 500 V AC |
EMR4-A... phase imbalance monitoring relay
|
Part Name Image |
Description |
Supply voltage |
Monitoring voltage |

|
EMR4-A400-1 |
- Monitors three-phase systems for phase imbalance
- Detects phase failure even at 95% voltage feedback from the motor
- Response delay: 0.5 s
- Phase imbalance response threshold adjustable from 5 – 15 %
- Phase sequence detection
- Supply voltage = voltage being monitored
|
380 – 415 V 50 Hz |
EMR4-W phase monitoring relay
|
Part Name Image |
Description |
Supply voltage |
Monitoring voltage adjustable from |
 |
EMR4-W500-2-C |
- Monitors three-phase systems for phase sequence, over- and undervoltage and phase failure (< 0.6 x Ue)
- 3-phase voltage monitoring within a range
- Selectable On-delay or Off-delay (0.1 – 10 s)
|
160 – 330 V AC |
Umin 300 – 380 V AC Umax 420 – 500 V AC |
| EMR4-W500-2-D |
300 – 500 V AC |
EMR4-W580-2-D |
300 – 500 V AC |
Umin 350 – 430 V AC Umax 500 – 580 V AC |
| |