DIL00M-DIL2M Accessories |
| PART # |
CONTACTOR FOR USE ON |
DESCRIPTION |
FUNCTION |
| |
|
RCBDIL48 |
DIL00AM, DIL00M, DIL0AM, DIL0M, DIL1AM, DIL1M, DIL2AM, DIL2M |
RC
Suppressors |
For
AC operated contactors, 50 – 60 Hz.
Drop-out delay should be taken into
consideration. |
|
RCBDIL250 |
|
RCBDIL415 |
| |
|
VGBDIL24 |
DIL00AM, DIL00M, DIL1AM, DIL1M, DIL2AM, DIL2M |
Varistor Suppressors |
For
AC operated contactors, 50 – 60 Hz,
(DIL00M to DIL4M115) and DC operated
contactors (DIL00M-G to DIL2AM-G).
DC operated contactors DIL3M80 to
DIL4M115 have an integrated varistor
suppressor as standard. |
|
VGBDIL48 |
|
VGBDIL250 |
|
VGBDIL415 |
| |
|
VGCDIL24 |
DIL00AM, DIL00M, DIL0AM, DIL0M, DIL1AM, DIL1M, DIL2AM, DIL2M |
Suppressors |
For
DC operated and AC operated contactors
DIL00M to DIL2AM |
|
VGCDIL48 |
|
VGCDIL250 |
|
VGCDIL415 |
| |
|
FDBDIL |
DIL00M,
DIL00AM, DIL0M, DIL0AM, DIL1AM, DIL1M, DIL2AM, DIL2M |
Free-wheel
diode suppressor |
For DC operated
contactors. Drop-out delay should be taken into consideration. |
| |
|
S1DIL00M |
DIL00M & DIL00AM |
STAR
BRIDGE
|
SOLID
JUMPER THAT CONNECTS ALL 3 POWER POLES TOGETHER. HAS NO INCOMING
WIRE TERMINAL CONNECTIONS. |
|
S1DIL0M |
DIL0M & DIL0AM |
|
S1DIL1M |
DIL1M & DIL1AM |
|
S1DIL2M |
DIL2M & DIL2AM |
|
S1DIL3M |
DIL3M80 |
|
S1DIL4M |
DIL4M115 |
|
DILM400-XS1 |
DILM185-DILM400 |
|
DILM500-XS1 |
DILM500 |
| |
|
P1DIL00M |
DIL00M & DIL00AM |
PARALLELING BRIDGE
|
SOLID
JUMPER THAT CONNECTS ALL 3 POWER POLES TOGETHER AND HAS A SINGLE
INCOMING TERMINAL CONNECTION. |
|
P1DIL0M |
DIL0M & DIL0AM |
|
P1DIL1M |
DIL1M & DIL1AM |
|
P1DIL2M |
DIL2M & DIL2AM |
| |
|
MVS-WB-00M |
DIL00(A)M |
REVERSING
JUMPER KIT
(1) MVDILM-Mechanical Interlock.
Must be purchased separately
|
Consisting of one 3 pole paralleling link (top) and reversing
link with A2 coil bridge (bottom). To form a reversing
contactor. An overload module cannot be directly connected to
the contactor and if needed must be mounted remotely. |
|
MVS-WB5MV |
DIL00(A)M+MVDILM
(1) |
|
MVS-WB-0M |
DIL0(A)M |
|
MVS-WB-11MV |
DIL0(A)M+MVDILM
(1)
DIUL0(A)M/MV |
|
MVS-WB-1M |
DIL1(A)M
DIUL1(A)M |
| |
|
BT480 |
All top
mounting auxiliary contacts |
Paralleling
Links |
Not insulated.
Standard Quantity: 100 |
| |
|
MVDILM |
DIL00(A)M, DIL0(A)M,
DIL1(A)M, DIL2(A)M |
MECHANICAL INTERLOCK KIT |
For
providing mechanical interlock between 2 contactors. No side
mount auxiliary contacts may be used except on the opposite
sides of the MV module. |
| |
| ZKDIL0M |
DIL0AM, DIL0M |
Control Circuit Terminals |
Pressure wire connectors mounted directly to the main
terminals for control circuit tap-off.
15A, 600V max., AWG 18 - 14 |
|
ZKDIL1M |
DIL1AM, DIL1M
DIL2AM, DIL2M |
| |
| HKDILM |
DIL1AM, DIL1M
DIL2AM, DIL2M |
Main Terminal |
For connecting large cross-sections,
For connection of:
up to 50 mm2 stranded
or 35 mm2 flexible with ferrule |
| |
| V0DIL |
DIL00M, DIL00AM, DIL0AM, DIL0M, DIL1AM, DIL1M,
DIL2AM, DIL2M |
Coupling
Connector |
0 mm distance between contactors |
| V5/15DIL |
5mm between contactors, for contactors with DC coil 15mm between
contactors, for mechanical interlock between contactors. |
| V10/A5DIL |
10mm between contactors, for mounting one side mounting auxiliary
contact between two contactors 5mm between contactors for
contactors with DC coil without permanent connection. |
| CS-TE |
ETS4-VS3 |
For screw mounting of ETS4-VS3 |
| |
|
TPE11DIL |
DIL00M-DIL2AM |
Top Mount ON Delay
Timer |
Snaps on
the top of the contactor and provided (1) Normally Open and (1)
Normally Closed Timed Contact. Adjustment ranges either (0.2-30)
or (20-180) seconds. |
|
TPD11DIL |
DIL00M-DIL2AM |
Top Mount OFF Delay
Timer |
V-GDIL
(24vdc) |
DIL00M |
Top Mount
Latching Module |
With
addition of this module a standard DIL00M becomes a Latching
relay. Pulse the DIL00M coil to Latch and pulse the module coil
to UNLATCH. |
V-DIL
(120VAC) |
DIL00M |
| |
| NDIL0M |
DIL0M |
4th Power
Pole. Adding this module to a standard 3 pole contactor makes it
a 4 Pole Power contactor |
Continuous Rating Open
35 Amps.
Continuous Rating Closed 30 Amps. |
| NDIL1M |
DIL1M |
Continuous Rating Open
55 Amps.
Continuous Rating Closed 44 Amps. |
| NDIL2M |
DIL2M |
Continuous Rating Open
75 Amps.
Continuous Rating Closed 60 Amps. |
| |
| BT483 |
DILEM
DIL00M to DILM820 |
Connection tabs for fast-on connectors |
For auxiliary contact and coil connections. Use
connectors with insulated sleeves. Standard quantity: 100 |
| |
| PL-DILT |
TPE11DIL
TPD11DIL |
Sealable Shrouds |
Cover is fastened via a screw. Sealable to prevent access. |
| |
| XGKA-U |
|
Universal Mounting Adapter |
Mounting:
Self Adhesive
with M3 screw or
cable tie Standard Quantity: 250 |
| |
| VS1DIL |
DIL00M-DIL2AM |
Contactor Mounted
incoming voltage interface module with integral
suppressor circuit. |
For
energizing of the contactor from low level 24 vdc inputs. The
VS1 and VS2 plug directly onto the DILM coil terminals |
| VS2DIL |
Contactor Mounted
incoming voltage interface module with out integral
suppressor circuit. |
|
ETS4-VS3 |
Any Contactor
with less than 2 amp coil |
SEPARATE
DIN RAIL MOUNT |
For energizing of the
contactor from low level 24 vdc inputs. |
| |