NZM10 Circuit Breaker
Auxiliary Contacts


Klockner Moeller NZM10 Circuit Breaker

NZM10 inverse time molded case circuit breakers are mode up of a switch block and protective trip module. Switch blocks and trip modules can be ordered separately and combined per the two tables shown below to suit any particular application.

AUXILIARY CONTACT

TYPE

Article Number

NHI STANDARD

AUXILIARY CONTACT

n Switching simultaneously with the main contacts.  They can be typically used for signaling, interlocking or switching auxiliary circuits such as a control circuit.

n Field Installable

NHI-NZM10

034943

VHI EARLY MAKE

AUXILIARY CONTACT

n Typically used for powering up the undervoltage trip prior to closing of main contacts and for control circuit interlocking tasks.

n CANNOT be used in conjunction with T-NZM10 remote control drive.

n Field Installable

VHI-NZM10

034944

RHI TRIP INDICATING

AUXILIARY CONTACT

n Actuating independently of the normal ON and OFF operations of the device, switching only when the device has tripped due to overcurrents or other tripping causes such as those initiated by voltage trips.

n Field Installable

RHI-NZM10

034945

SIGNALING BLOCK

3 Poles

n Differential fault indication and visual display of breaker operating states:

-(1) + (2) tripping due to short circuit.

-(2) tripping due to overload and general trip condition.

-(3) overload early warning signal in the event that the long time response setting is about to be exceeded (i.e. useful for load shedding purposes).

n Each function signals via a pair of contacts (1 N.O. and 1 N.C.).

n Mounts directly onto lower portion of circuit breaker

n Required supply voltage: 24-230 V, AC or DC.

n Field Installable

M-NZM10

034946


Return to NZM10

Legacy Circuit Breakers


 

   Wood Dale, Illinois  -  Englewood, Florida 
Local  (941) 473-0073 - Fax (941) 473-0987

Toll Free: 1 (866) 595-9616

 

Buy Klockner Moeller Direct from KMparts.com
 
- IN STOCK-

Our Mascot - Free rubber duck with every purchase!
Visit our Main Site at: KlocknerMoeller.com

 

For your convienance all Major Credit Cards Taken for Same Day Shipping of Moeller Electric Parts!
2005 PDF Catalog

EASY 500-700-800 PDF Brochure

2005 Automation PDF Catalog

KM News


A to Z Parts Index

Moeller Electric Catalogs

Search our Site

Klockner Moeller NZM4 - NZMH4 - NZM6 - NZM6B - NZM9 - NZM11 - NZM12 - NZM14
Moeller Electric Contactors. DIL0M - DIL0AM - DIL00M - DIL00AM - DIL1M - DIL1AM - DIL2M - DIL2AM - DIL3M - DIL4M115
Klockner NZM7 and NZM10
Moeller 11DIL - 11DILM -22DIL - 22DILM - 31DIL - 31DILM - 40DIL - 40DILM - 13DIL - 13DILM - 11SDILM - 22SDILM.
Moeller Electric Cam Switches
Klockner Moeller AT0 Safety Limit Switches
Moeller Electric timing Relays
Moeller DILET series timers to match the DILE series relays.
Klockner Motor Overload Protection Z00, Z1,Z2, Z3, Z4, Z5, ZE
Modular stack lights from Klockner Moeller